Chemical analysis

We conduct chemical analyses to identify tiny alterations in electroplating electrolytes which could impair deposition conditions and cause layer defects.

To characterize electrolytes, we have titroprocessors for analyzing ions such as nickel and chrome, as well as ion chromatography (IC) and high performance liquid chromatography (HPLC) for characterizing organic additives and cracking products.

As an independent and neutral partner, we see it as our duty to identify potential sources of error, link them to defects and develop appropriate corrective measures.